TECHZONE with CALLA Field Panels
- Edge: Square Tegular 9/16"
- Dimensions: 24" x 24"
- Thickness: 1-1/4"
- Shape: Rectangle
-
Acoustics:
NRC: 0.85CAC: 39 - Fire Performance: Class A (UL)
- Light Reflectance: 85%
- Face Profile: 9/16"
Product Details
Acoustics
Acoustical options available. |
|
---|---|
Sound Absorption (NRC)
A measure for rating the overall sound absorption of a material when used in an enclosed architectural space where sound is reflected at many angles of incidence. A ceiling system with an NRC < 0.50 is low performance, an NRC > 0.70 is high performance. |
0.85 |
Sound Blocking (CAC)
A measure for rating the performance of a ceiling system as a barrier to airborne sound transmission through a common plenum between adjacent closed spaces. A ceiling system with a CAC < 25 is considered low performance, whereas one with CAC of 35 or higher is high performance. |
39 |
Fire | |
Fire Performance
|
Class A (UL) |
Light Reflectance
A high light reflective ceiling – LR 0.83 or greater, per ASTM E1477-98 as referred to in ASTM E1264-98 – makes lighting systems, especially indirect lighting, more effective while further reducing energy costs and consumption. LR values apply to White panels only. |
85% |
Sag/Humidity Resistance
Ceiling panels maintain humidity and sag resistance. |
HUMIGUARD Plus |
Insulation Value
|
R Factor-BTU: 2.90 BTU R Factor-Watts: 0.445 m2 K/W |
Mold/Mildew Resistance
Ceiling panels with BIOBLOCK performance resist the growth of mold and mildew on the panel surface. |
BIOBLOCK |
Disinfectability
|
|
Fog
May be fogged following CDC recommendations using EPA-approved disinfectant cleaners per Armstrong Cleaning & Disinfecting Guidelines |
|
Durability
|
|
Soil Resistance
Excellent resistance to dirt and/or grease for lasting value and performance. |
|
Impact Resistance
Surface impact based on the Striking Ball Impact Test, modified ASTM D1037 procedure. |
|
Scratch Resistance
Excellent resistance to surface scratching, scuffing or chipping as per Hess Rake Test. |
|
Washability
Offers superior wash resistance without compromising panel finish integrity, using a washability tester as per ATSM D4828. |
Material
|
Mineral Fiber |
---|---|
Texture
|
Smooth |
Surface Finish
|
Factory applied latex paint |
Shape
|
Rectangle |
Weight
|
2.25 lbs/SF |
Thermal Energy Storage Capacity
Minimum thermal energy storage capacity from 62ºF to 83ºF per ASTM C1784 |
35 btu/SF |
Sq Ft (Sq Ft / Carton)
|
16 |
Pieces / Carton
|
4 |
ASTM Classification
|
Type: A, Form: A2.2, Pattern: G |
Installation Method
|
Grid (Suspended) |
Made In U.S.A. Of Domestic and Global Content
|
Yes |
Accessibility
Downward access for panels minimizes panel damage. |
Yes |
Recyclable/Extended Producer Responsibility
|
Recycled Content
|
Energy Management
|
Sourcing of Raw Materials
|
Construction Waste
|
Material Ingredient Reporting
|
Regional Materials
Location Dependent
|
Low emitting/materials
|
Design for Flexibility
|
Lighting Quality
|
EPD
|
Acoustics
|
Biobased Materials
|